APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20523 Issued:1987-03-06
Revised:2012-01-25
Style 20523 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG solid or stranded, tinned or bare copper.
InsulationExtruded PE, 13 mils minimum average thickness, 12 mils minimum thickness at any point.
ShieldOptional.
CoveringExtruded PE, 10 mils minimum thickness at any point.
JacketExtruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.