APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20525 Issued:1986-03-09
Revised:2012-07-28
Style 20525 Flat Ribbon Cable

Rating60, 80 deg C, 30 Vac, Horizontal flame.
InsulationLabeled style 1354.
AssemblyTwo to 20 insulated singles. May be heat or solvent bonded. Insulation is built with inner covering (optional), inner shield (optional), middle covering (optional), outer shield (optional), outer covering (optional).
ShieldInner/Outer shield - Optional.
CoveringInner covering optional - Extruded PVC, 2 mils minimum or 0.5 mils or heavier polyester film. Middle covering optional-Extruded PVC or heat sealed PVC tape, Polyamide Polyester, PVDF, FEP or PTFE, ETFE, or lacquered braids, 2 mils minimum at any point or 0.5 mils or heavier Polyester film or Polyester-Polyethylene laminated film. Outer covering optional - Extruded PVC or heat sealed PVC tape, Polyamide, Polyester, PVDF, FEP, PTFE, ETFE, irradiated PE, irradiated PVC or lacquered braid, 2 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Class 2 circuits of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024