APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20529 Issued:1987-04-17
Revised:2012-03-30
Style 20529 Multiple-conductor cable using non-integral jacket

Rating105 deg C, 300 Vac, Horizontal Flame.
Conductor50 - 10 AWG, solid or stranded.
AssemblyFlat cable labeled or complying with manufacturer's AWM procedure. Multiple layers of the insulated conductor assembly may be used providing the layers are separated by 2 mils minimum thickness polyester film.
ShieldOptional - or shield may be braided aluminum faced polyester or metalized polyester tape with or without drain wire.
JacketExtruded PVC, 30 mils min average thickness, 24 mils minimum thickness at any point, 100 mils max thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection or internal wiring of electronic equipment, and business machines.

UL and the UL Logo are trademarks of UL LLC © 2024