APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2053 Issued:1959-05-01
Revised:2011-10-27
Style 2053 Style SPT-1 Cord.

Rating90 deg C, 300 Vac, FT2 flame, Oil Resistant 60 deg C or 80 deg C (optional).
Conductor18 AWG consisting of No.30 AWG or smaller stranded, tinned or bare copper.
InsulationIntegral with Jacket. PVC, 28 mils min average, 25 mils minimum at any point.
AssemblyFour conductors, same as type SPT-1, except for a nominal 80 mil separation between conductors. The following minimum (pin gauge) dimensions shall apply: Wall thickness: 0.028 in., Web thickness: 0.070 in., Wall after rip: 0.028 in..
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electric refrigerators where installed within separate metal enclosure or between walls of the cabinet, and where exposed to temperatures not exceeding 90 deg C. Dependent upon the compound used, the tag may add the statement: and where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable). Polarity identification may be omitted.
 
UL and the UL Logo are trademarks of UL LLC © 2024