APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20538 Issued:1987-04-30
Revised:2012-07-07
Style 20538 Flat Cable

Rating60 deg C, 30 Vac, Horizontal flame.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo to 100 singles laid parallel. Insulation is built with Inner covering (optional), shield (optional), and Outer covering (optional).
ShieldOptional - Shield may be aluminum/polyester/PVC film.
CoveringInner Covering - Extruded PVC, minimum 2 mils thick, or polyester or polyester/PVC film on both sides of assembly. Film has adhesive layer. Outer Covering - Optional - Extruded PVC, min 5 mil thick.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment in Class 2 circuits only.

UL and the UL Logo are trademarks of UL LLC © 2024