Rating | 80 deg C, 30 Vac, VW-1 flame. |
|
Conductor | 40 AWG minimum. Material not specified. |
|
Insulation | Extruded FRPE or estruded PE or estruded PP, Solid or cellular, 3 mils minimum average thickness, 2 mils minimum thickness at any point, 125 mils max. May be irradiated. |
|
Assembly | Two to 100 singles laid parallel. If laminated construction, insulated singles may be bonded to one or between two sheets of inner covering. |
|
Shield | Inner shield - Metal faced polyester tape. Outer shield, two sheets of aluminum faced polyester tape laminated over the conductor assembly. |
|
Covering | Covering - Extruded PVC or laminated polyester film minimum 0.5 mils minimum between shields |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | As internal wiring in Class 2 circuits of electronic equipment. |
|