APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20539 Issued:1987-05-18
Revised:2012-04-26
Style 20539 Extruded Flat Ribbon Cable with Extruded Non-Integral Jacket

Rating80 deg C, 30 Vac, VW-1 flame.
Conductor40 AWG minimum. Material not specified.
InsulationExtruded FRPE or estruded PE or estruded PP, Solid or cellular, 3 mils minimum average thickness, 2 mils minimum thickness at any point, 125 mils max. May be irradiated.
AssemblyTwo to 100 singles laid parallel. If laminated construction, insulated singles may be bonded to one or between two sheets of inner covering.
ShieldInner shield - Metal faced polyester tape. Outer shield, two sheets of aluminum faced polyester tape laminated over the conductor assembly.
CoveringCovering - Extruded PVC or laminated polyester film minimum 0.5 mils minimum between shields
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseAs internal wiring in Class 2 circuits of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024