APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20540 Issued:1987-05-18
Revised:2012-03-21
Style 20540 Extruded Flat Ribbon Cable with Extruded Non-Integral Jacket

Rating80 deg C, 30 Vac, VW-1 flame.
Conductor40 AWG minimum.
InsulationExtruded FRPE or PE or PP, Solid or cellular, or XLFRPE or XLPE or XLPP.
Assembly2-100 singles laid parallel. If laminated construction, insulated singles may be bonded to one or between two sheets of inner covering. Insulation is built with Inner/ Outer shield and jacket.
ShieldInner Shield - Metal faced polyester tape. Outer Shield - two sheets of aluminum faced polyester tape laminated over the conductor assembly.
CoveringInner Covering - Extruded PVC or laminated polyester film with 0.5 mils minimum thickness.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseAs internal wiring or external interconnection in Class 2 circuits of electronic equipment.