| Rating | 60, 80 deg C, 30 Vac, Cable and VW-1 flame. |
|
| Conductor | AWG 36 - 18 AWG solid or stranded. |
|
| Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
| Assembly | Two to 100 singles laid parallel in one plane and bonded or laminated to one or between two PVC sheets. |
|
| Shield | Metal faced polyester tape. |
|
| Covering | Extruded PVC or FRPE, 2 mils minimum thickness at any point. |
|
| Jacket | Extruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | As internal wiring or external interconnection in Class 2 circuits of electronic equipment. |
|