APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20542 Issued:1987-05-18
Revised:2011-08-01
Style 20542 Bonded or Laminated Flat Ribbon Cable

Rating60, 80 deg C, 30 Vac, Cable and VW-1 flame.
ConductorAWG 36 - 18 AWG solid or stranded.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo to 100 singles laid parallel in one plane and bonded or laminated to one or between two PVC sheets.
ShieldMetal faced polyester tape.
CoveringExtruded PVC or FRPE, 2 mils minimum thickness at any point.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseAs internal wiring or external interconnection in Class 2 circuits of electronic equipment.