Rating | 80 deg C, 30 Vac, VW-1 flame. |
|
Conductor | 40 AWG minimum, solid or stranded. |
|
Insulation | Extruded FRPE, extruded foamed FRPE, extruded XLFEPE, extruded PE, extruded foamed PE, extruded XLPE, 4 mils minimum thickness at any point, 100 mils maximum. |
|
Assembly | 2 - 100 Insulated singles or groups of insulated singles laid parallel or twisted together length of lay not specified. Barrier layer or fillers optional. |
|
Shield | Inner shield - Over any and/or all singles. Outer shield - Optional |
|
Covering | Inner Covering - Optional - over any or all singles - 2 mils minimum thickness at any point extruded PVC, Nylon, Polyester, PVDF, ETFE or Lacquered Braid. Outer Covering - Optional, extruded PVC, 5 mils minimum thickness at any point, 40 mils maximum. |
|
Jacket | Extruded PVC, 30 mils min average, 24 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal or external wiring of low energy non-hazardous circuits in audio and video equipment. |
|