APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20555 Issued:1987-08-21
Revised:2012-03-27
Style 20555 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor36 AWG - 22 AWG, solid or stranded.
InsulationExtruded ECTFE, extruded FEP, extruded PVDF or extruded TPE, 4 mils minimum average thickness, 3 mils minimum thickness at any point.
AssemblyTwo to six conductors.
ShieldOptional.
JacketExtruded ECTFE, extruded FEP, extruded PVDF or extruded TPE, 5 mils minimum average thickness, 4 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.