APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20561 Issued:1987-11-04
Revised:2012-01-12
Style 20561 Flexible Ribbon Cable

Rating105 deg C, 60 Vac, Horizontal flame.
Conductor36 AWG - 12 AWG flat or round, straight or irregular shaped. Round sizes 12 through 36 AWG. Flat conductor maximum thickness 20 mils.
InsulationOn each side of the conductors a minimum thickness of 2 mils PETP and 1 mil polyester adhesive or 1 mil PETP and 2 mil PVC adhesive. Minimum 5 mil insulation edge width and minimum 6 mils between conductors.
AssemblyTwo through 150 conductors
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment Class 2 or Class 3 circuits only (such as computers and business machines).