| Rating | 200 deg C, 120 Vac, 240 Vac, 300 Vac, Horizontal flame. |
|
| Conductor | 20 AWG - 14 AWG stranded, tinned or bare. Over the uninsulated conductors is an extruded semi-conductive high temperature thermoplastic or thermoset conductive covering. |
|
| Insulation | Extruded FEP, 20 mils min average, 18 mils minimum at any point. |
|
| Assembly | Two to three conductors. In lieu of one uninsulated conductor, in a three conductor cable, a labeled insulated single (having a min rating of 200 C-300 V) may be laid parallel to the conductive core. |
|
| Shield | Optional. |
|
| Jacket | Optional - Extruded FEP, 15 mils min average, 12 mils minimum at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Pipe heating cable where the acceptability of the combination is to be determined by Underwriters Laboratories Inc. |
|