APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20566 Issued:1987-12-02
Revised:2018-04-09
Style 20566 Flat Ribbon Cable

Rating105 deg C, 90 Vac, Horizontal flame.
Conductor32 AWG - 12 AWG round or flat.
Insulation1.5 mils minimum of polyester adhesive bonded to 1.5 mils minimum of biaxially oriented polyethylene terephthalate minimum 10 mils insulation on width on outside edges of conductors and 10 mils minimum insulation width between adjacent conductors. Length of insulated conductors not specified.
AssemblyTwo through 150 conductors may be straight or irregular shaped and laid parallel and in one plane. Minimum width of 10 mils and maximum width of 100 mils.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024