APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20567 Issued:1987-12-11
Revised:2012-07-29
Style 20567 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 30 Vac, Cable flame.
InsulationLabeled or complying with the manufacturers procedure
AssemblyThe cable consists of two groups of insulated singles or multiconductor cables labeled or complying with manufacture's AWM Procedure having a minimum rating of 60 deg C and 30 Volts. The two groups are laid parallel with an overall jacket and may have an interconnecting web.
ShieldEach section may be shielded.
JacketPUR, 30 mils min average, 24 mils minimum at any point; width or thickness of web not specified. The maximum overall core diameter of either group is 0.250 in.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal wiring

UL and the UL Logo are trademarks of UL LLC © 2024