APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20569 Issued:1988-01-11
Revised:2012-07-27
Style 20569 Jacketed Cable

Rating60, 80, 90, 105 deg C, 300 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's procedure.
AssemblyConsists of a ribbon cable folded or spiraled layers or shielded pairs. Section may be slit into singles of two to 100 inches in length. Fillers optional. Singles, twisted pairs or groups of singles may be cabled with the ribbon cable.
ShieldOptional.
JacketPVC
dia of cable under jacket is 0.700 inches or less*10 mils min average8 mils minimum at any point
0.701-1.000 dia20 avg16 min
1.001-1.500 dia30 avg24 min
1.501-2.500 dia45 avg36 min
2.501-4.000 dia60 avg48 min
4.001 dia and larger80 avg64 min
*Major diameter if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024