APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20573 Issued:1988-03-25
Revised:2011-08-22
Style 20573 Bonded or Laminated Flat Ribbon Cable

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor36 AWG - 18 AWG, solid or stranded.
InsulationExtruded or heat laminated PVC, 12 mils minimum average thickness, 10 mils minimum thickness at any point.
AssemblyTwo through 150 conductors laid parallel. Sections of the cable may be split into singles or groups of conductors.
ShieldOptional.
CoveringOptional, extruded PVC, 5 mils minimum thickness at any point, 80 mils maximum thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electronic Equipment.