Rating | 60 deg C, 30 Vac, Cable flame (construction B), Horizontal flame (construction A). |
|
Conductor | 40 AWG minimum solid or stranded round, tinned or bare copper. |
|
Insulation | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional. |
|
Covering | Optional - Extruded PVC, 3 mils minimum at any point may be extruded over shielded or unshielded twisted singles, individual groups of twisted singles, or the complete insulated conductor assembly. |
|
Jacket | Extruded PVC |
| dia of cable under jacket is 0.350 inches or less* | (const A) | 15 mils min avg | 12 mils min at any point |
| dia of cable under jacket is 0.350 inches or less | (const B) | 30 avg | 24 min |
| 0.351-0.700 dia | (const A) and (const B) | 30 mils avg | 24 mils min |
| 0.701-1.000 dia | (const A) and (const B) | 40 avg | 36 min |
| 1.001-1.500 dia | (const A) and (const B) | 54 avg | 48 min |
| *Major dia if cable is flat or oval. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Construction A: Internal Wiring in Electronic Equipment. Construction B: External Wiring in Electronic Equipment. |
|