Rating | 60 deg C, 30 Vac, Horizontal Flame (construction A), Cable flame (construction B). |
|
Insulated Conductor | No. 40 AWG minimum. Labeled or complying with manufacturer's AWM proceure. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Covering | Optional - Extruded PVC, 3 mils minimum thickness at any point, may be extruded over shielded or unshielded twisted singles, individual groups of twisted singles, or the complete insulated conductor assembly. |
|
Shield | Optional. |
|
Jacket | Extruded PVC |
| dia of cable under jacket* | contruction | min. avg | min. at any point |
| 0.350 inch or less | (const A) | 15 mils | 12 mils |
| 0.350 inch or less | (const B) | 30 mils | 24 mils |
| 0.351-0.700 inch | (const A) and (const B) | 30 mils | 24 mils |
| 0.701-1.000 inch | (const A) and (const B) | 40 mils | 36 mils |
| 1.001-1.500 inch | (const A) and (const B) | 54 mils | 48 mils |
| *Major dia if cable is flat or oval. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Construction A: Internal Wiring of Class 2 Circuits in Electronic Equipment. Construction B: External Wiring of Class 2 Circuits in Electronic Equipment. |
|