Rating | 105 deg C, 300 Vac, FT2 flame. |
|
Conductor | Two 16-18 AWG, bare stranded (36-34 AWG strands) copper and one 22-26 AWG bare, stranded (36 AWG strands) copper. A 3 mil minimum at any point covering of nylon, polyester or propylene shall be applied directly over the 22-26 AWG copper conductor. |
|
Insulation | Extruded integral PVC insulation and jacket, 45 mils min average, 40 mils minimum at any point. |
|
Assembly | Three conductors, same as for Type SPT-2. The two 16-18 AWG conductors shall be parallel and the 22-26 AWG conductor shall be located between the 16-18 AWG conductors. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Special purpose cord to be used only as a power-supply cord for appliances employing an attachment plug with a water detection circuit. |
|