APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20588 Issued:1988-07-26
Revised:2012-05-24
Style 20588 Multiple-Conductor Cable using Non-Integral Extruded Jacket

Rating80 deg C, 300 Vac, Cable Flame.
Conductor22 AWG, Solid or Stranded Round.
InsulationExtruded PVC, 15 mils minimum average, 13 mils minimum at any point.
AssemblyThree conductors, same as type SVT. May be helicoiled in form of helix.
ShieldOptional.
CoveringOptional.
JacketExtruded TPU
diameter of cable under jacket in inchesmils minimum averagemils minimum at any point
0.425 or less3024
0.426-0.7004536
0.701-1.5006048
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSpecial use power supply cord where the acceptability of the combination is to be determined by Underwriters Laboratories

UL and the UL Logo are trademarks of UL LLC © 2024