APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20589 Issued:1988-09-12
Revised:2012-07-25
Style 20589 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 300 Vac, FT2 flame.
ConductorTwo 18 AWG - 16 AWG and two 16-18 AWG and two 22-24 AWG copper conductors, may be tinned or untinned, solid or stranded.
InsulationExtruded PVC, 15 mils min average, 13 mils minimum at any point.
AssemblyTwo conductors, same as type SJT cord, color coding of insulation not required.
JacketExtruded PVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSpecial purpose cord to be used only as an external power supply cord for appliances employing an attachment plug with a water detection circuit.