Rating | 90 deg C, 120 Vac, 240 Vac, 300 Vac, Horizontal Flame, Optional - 60 deg C Moisture Resistant |
|
Conductor | 28 AWG - 16 AWG, solid or stranded. Extruded core carbon-loaded XLPO over the conductor as a conductive layer. |
|
Covering | Optional. Extruded polyolefin, 6 mils minimum average thickness. |
|
Assembly | 2-4 conductors. Monitor Wire - Optional - Recognized Appliance Wiring Material style having a minimum rating of 90 deg C, 300 V. |
|
Insulation | Extruded TPE, 28 mils minimum thickness at any point. |
|
Shield | Optional. |
|
Jacket | Optional. Extruded TPE, 20 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Pipe heating cable. |
|