APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20591 Issued:1988-08-09
Revised:2012-01-12
Style 20591 Flat ribbon cable.

Rating80 deg C, 150 Vac, Horizontal flame.
Conductor36 AWG - 20 AWG solid or stranded round, tinned or bare copper.
InsulationExtruded PVC, 6 mils min average, insulated singles bonded together, 6 mils average, 5 mils min at any point after rip.
AssemblyTwo through 150, laid parallel.
ShieldOptional.
CoveringOptional - PVC, 5 mils min at any point, 80 mils max.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment equipment such as computers and electric business machines.