APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20594 Issued:1988-09-06
Revised:2012-01-29
Style 20594 Laminated Flat Ribbon cable

Rating60 or 80 deg C, 30 Vac, Horizontal flame.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyThe cable consists of a top layer of Aluminum/Polyester, a row of (two or more) insulated singles (laid parallel), an intermediate layer of Aluminum/Polyester/Aluminum, a second row of (two or more) insulated singles (laid parallel), and a bottom layer of Aluminum/Polyester laminated together. Each row of singles may employ one or more insulated grounding conductors. The minimum distance between the edge and the first conductor shall be 30 mils.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances and electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024