APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20601 Issued:1988-12-08
Revised:2012-03-21
Style 20601 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating80 deg C, 300 Vac, horizontal flame.
InsulationLabeled or complying with Manufacturer's AWM procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional - A 6 mil thick or thicker PVC covering may be extruded over the conductor assembly.
JacketExtruded PVC
Diameter of core assembly under jacket (inches) ¿Minimum average thickness (mils)Minimum thickness at any point (mils)
0.700 or less3024
0.701-1.0006048
1.001-1.5008064
Major diameter if cable is flat or oval
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring and external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024