APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20609 Issued:1989-02-02
Revised:2012-05-02
Style 20609 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 30 Vac, Horizontal flame.
Conductor26-20 AWG, solid or stranded.
InsulationExtruded PVC, 5 mils minimum thickness at any point.
AssemblyTwo insulated singles twisted together.
CoveringExtruded nylon, 2 mils minimum thickness or 2 mils minimum diameter cotton thread wound over the conductor assembly.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Class 2 circuits in electronic equipment.