APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20616 Issued:1989-05-24
Revised:2012-07-30
Style 20616 Bonded Flat Ribbon Cable

Rating105 deg C, 300 Vac, Horizontal flame.
Conductor38 AWG - 20 AWG bare, tinned or plated, round or flat conductors. Min thickness of 1.5 mils;max thickness of 6 mils. Min width of 10 mils; max width of 100 mils.
InsulationPET, on each side of the conductors a 2 mil min at any point wall with a min 1 mil water based acrylic adhesive backing bonded together. Min 15 mils insulation width on outside edges of conductors and 25 mils min width insulation between adjacent conductors. Length of insulated conductors not specified.
AssemblyConductors may be straight or irregular shaped and in one plane.
ShieldOptional.
CoveringOptional.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024