APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20619 Issued:1989-07-25
Revised:2012-07-24
Style 20619 multiple conductor cable with extruded insulation

Rating105 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG min, material not specified.
InsulationETFE or FEP or PET, PETP or PFA or POLYESTER or POLYIMIDE or PTFE, TFE or PVC, solid or cellular, 3 mils min average, 3 mils min at any point.
AssemblyTwo to ten conductors; Insulation is built with an optional inner shield, jacket, optional outer shield, and optional covering.
ShieldInner/Outer - Optional.
Covering(Optional) PTFE, FEP, ETFE, PVC or PFA min wall at any point 2 mils, or PETP with a PVC or polyester adhesive (Milene) min wall at any point 2 mils.
JacketETFE or FEP or PET, PETP or PFA or PVC, 2 mils min average, 2 mils min at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024