APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2062 Issued:1959-05-01
Revised:2012-07-26
Style 2062 Multiple-Conductor Cable Using Non-Integral Jacket

Rating60 deg C, 300 Vac, Horizontal flame.
Conductor24 AWG solid or stranded copper, consisting of No. 34 or 36 AWG copper strands.
InsulationExtruded PVC, 15 mils min average, 14 mils minimum at any point.
Assemblythree conductor, Insulated conductors shall be wrapped of around a core of one end of a 150-4/4 glass fibre thread. The lay of conductors shall be a maximum 1-3/4 in. and the outer interstices shall be filled with 10/1 soft cotton. Overall diameter of cord shall be 0.205 in. minimum.
JacketExtruded PVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor Use Only With Electric Blankets.

UL and the UL Logo are trademarks of UL LLC © 2024