Rating | 90 deg C, 120 Vac, 240 Vac, 300 Vac, Horizontal flame, Moisture Resistant 75 deg C. |
|
Conductor | 20 AWG - 14 AWG solid or stranded round. |
|
Insulation | Extruded TPE, 20 mils min average, 18 mils minimum at any point. See facing page for compound designation. |
|
Misc. | Conductive Core -Over the conductor is an extruded carbon loaded (radiation cross-linked) polyolefin, thickness not specified. |
|
Assembly | Two to three conductors. |
|
Shield | Optional. |
|
Covering | Optional - extruded modified polyurethane, extruded polyester or extruded thermoplastic elastomer, 6 mils min at any point. |
|
Jacket | Extruded TPE, 18 mils min average, 14 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Pipe Heating and Roof and Gutter Deicing cable where the acceptability of the combination is to be determined by Underwriters Laboratories Inc. |
|