APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20628 Issued:1989-10-30
Revised:2012-07-20
Style 20628 Multiple conductor cable using non-integral jacket

Rating90 deg C, 120 Vac, 240 Vac, 300 Vac, Horizontal flame, Moisture Resistant 75 deg C.
Conductor20 AWG - 14 AWG solid or stranded round.
InsulationExtruded TPE, 20 mils min average, 18 mils minimum at any point. See facing page for compound designation.
Misc.Conductive Core -Over the conductor is an extruded carbon loaded (radiation cross-linked) polyolefin, thickness not specified.
AssemblyTwo to three conductors.
ShieldOptional.
CoveringOptional - extruded modified polyurethane, extruded polyester or extruded thermoplastic elastomer, 6 mils min at any point.
JacketExtruded TPE, 18 mils min average, 14 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePipe Heating and Roof and Gutter Deicing cable where the acceptability of the combination is to be determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024