APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2063 Issued:1959-05-01
Revised:2012-03-09
Style 2063 Multiple-Conductor Cable with Extruded Non-Integral Jacket.

Rating60 deg C, 300 Vac, Horizontal Flame.
Conductor24 AWG consisting of No. 34 or 36 AWG copper strands, tinned or bare copper.
InsulationExtruded PVC, 15 mils minimum average, 14 mils minimum at any point.
AssemblyConsists of four conductors, Insulated conductors shall be wrapped around a core of three ends of 150-1/3/3 glass fibre threads, or one end of a minimum of 27 filaments of 150-1/0 glass fibre threads. The lay of conductors shall be a maximum 1 in. Overall minimum diameter of cord shall be 0.220 in.
JacketExtruded PVC, 30 mils minimum average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSpecial. For Use Only With Electric Blankets.

UL and the UL Logo are trademarks of UL LLC © 2024