Rating | 80 deg C, 30 Vac, Horizontal flame. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Two to 200 insulated singles, twisted pair triads or quads laid parallel in one plane, bonded together or to a PVC-Polyester or PVC covering in such a fashion to form a flat ribbon type cable. May include mixed AWG sizes. Manufacturer shall maintain a record of all singles used in each cable. Sections may be slit into singles or groups of conductors. Insulation is built with inner covering (optional), shield (optional), and outer covering (optional). |
|
Covering | Optional - One or two sheets of PVC or polyester/PVC laminated film, each sheet is 2 mil min at any point, laminated over the cable assembly. Film covering may be perforated. Hole dia and pattern is not specified. |
|
Shield | Optional. |
|
Covering | Optional.PVC, 5 mils min at any point, 80 mils max. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electronic equipment. |
|