APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2064 Issued:1959-05-01
Revised:2012-07-12
Style 2064 Multiple Conductor Cable with Extruded Insulation with an Extruded Non-integral Jacket.

Rating60 deg C, 300 Vac, FT-2 flame.
Conductor24 AWG consisting of No. 34 or 36 AWG strands.
InsulationExtruded PVC, 15 mils min average, 14 mils minimum at any point.
AssemblyFive conductors, insulated conductors shall be wrapped around a core of four ends of 150-1/3/3 glass fibre threads or one end of a minimum 32 filaments of 150-1/0 glass fibre threads. The lay of conductors shall be a maximum of 1-1/8 in. Overall diameter of cord shall be 0.225 in. minimum.
JacketExtruded PVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor Use Only With Electric Blankets.

UL and the UL Logo are trademarks of UL LLC © 2024