APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20644 Issued:1990-03-05
Revised:2012-01-25
Style 20644 Multiple-conductor cable using non-integral jacket

Rating60, 75, 90, 105 deg C, 300 Vac, Horizontal flame.
Conductor18 AWG - 10 AWG, solid or stranded.
InsulationExtruded PVC
18-16 AWG35 mils minimum average thickness32 mils minimum thickness at any point
15-14 AWG40 avg36 min
13-12 AWG45 avg41 min
11-10 AWG55 avg50 min
AssemblyTwo or three conductors, same as NISPT cords for thickness, etc., outlined on this Style Page. May employ notched, rippable jacket construction.
JacketExtruded PVC
18-16 AWG30 mils minimum average thickness24 mils minimum thickness at any point
15-14 AWG40 avg30 min
13-12 AWG50 avg38 min
11-10 AWG55 avg42 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal or external wiring.