APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20646 Issued:1990-03-16
Revised:2012-07-25
Style 20646 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 300 Vac, Cable flame.
ConductorStranded only
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional.
JacketExtruded PVC, for if the diameter of cable under jacket is 1.000 inches, or less 60 mils min average, 48 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFlexible External Interconnection on Elevators Between Wiring on the Car and Devices on the Car Door or Gates.

UL and the UL Logo are trademarks of UL LLC © 2024