Rating | 105 deg C, 300 Vac, FT2 Flame, Oil Resistant 60 deg C or 80 deg, Gasoline Resistant. |
|
Conductor | 26-18 AWG, Solid or Stranded Round. |
|
Insulation | Labeled or complies with the manufacturers procedure |
|
Assembly | Two or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, all groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or a thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors. |
|
Shield | Optional - Tinned soft iron shield applied as a braid with an overall polyester tape wrap. |
|
Jacket | Extruded PVC |
| diameter of cable under jacket in inches | mils minimum average | mils minimum at any point |
| 0.350 or less | 30 | 24 |
| 0.351-0.450 | 40 | 32 |
| 0.451-0.550 | 50 | 40 |
| 0.551-0.750 | 60 | 48 |
| 0.751-0.950 | 70 | 56 |
| 0.951-1.200 | 80 | 64 |
|
Covering | Extruded Nylon |
| diameter of cable under jacket in inches | mils minimum thickness at any point |
| 0.350 or less | 4 |
| 0.351 - 0.450 | 5 |
| 0.451 - 0.550 | 6 |
| 0.551 - 0.750 | 7 |
| 0.751 - 0.950 | 8 |
| 0.951 - 1.200 | 9 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection of electronic equipment. |
|