APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20649 Issued:1990-06-07
Revised:2012-07-29
Style 20649 Bonded or laminated flat ribbon cable

Rating105 deg C, 250 Vac, Horizontal flame.
Conductor15 AWG - 1 AWG Flat.
InsulationExtruded Polyamide 5.0 mils min average, 4.0 mils min at any point. See Facing Page for compound.
AssemblyTwo conductors laid in parallel. Width variable from 400-1500 mils. Thickness variable from 8-35 mils. Web thickness, 80 mils min at any point.
BraidExtruded Polyamide 5.0 mils min average, 4.0 mils min at any point. See Facing Page for compound.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring

UL and the UL Logo are trademarks of UL LLC © 2024