APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20651 Issued:1990-06-27
Revised:2012-01-12
Style 20651 Flat ribbon cable

Rating75 deg C, 125 Vac, Horizontal flame.
ConductorCopper alloy or hard drawn conductor 3.6 mils min and 11.3 mils max dia shall be wound spirally for a min of 27 turns per in to a max of 70 turns per in on a Polyester, Nylon, Fiberglass, Cotton or Rayon yarn core.
InsulationPVC, 20 mils min average, 18 mils minimum at any point.
AssemblyTwo conductors, similar to type SPT cord except the insulation is 20 mils min average, 18 mils min at any point wall of PVC and shall maintain at lease 18 mils of thickness after ripping at the web.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseIn Electrically Heated Blankets.