APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20655 Issued:1990-08-09
Revised:2012-04-17
Style 20655 Multiple-conductor cable using non-integral jacket

Rating80, 105 deg C, 30 Vac, Cable flame.
Insulated ConductorRecognized Magnet Wire (OBMW2), Type MW-28C.
AssemblyTwo to fifty singles, twisted pairs of groups of twisted singles, twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
JacketExtruded PVC, dia. or 0.500 inches or less, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection or internal wiring of electronic equipment.