APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20661 Issued:1990-09-10
Revised:2013-03-06
Style 20661 Multiple-Conductor Cable Using Extruded or Non-Extruded Non-Integral Jacket

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG min., solid or stranded.
InsulationSolid or cellular FRPE or PE or XLPE with POLYESTER or PVC adhesive, 3 mils minimum thickness at any point.
AssemblyTwo to ten Insulated singles or groups of insulated singles laid parallel or twisted together.
ShieldInner and outer shield are optional.
JacketExtruded PTFE or FEP, ETFE, PVC or PFA with 2 mils minimum wall thickness at any point or PETP with a PVC or polyester adhesive, with 2 mils minimum wall thickness at any point.
CoveringOptional, over jacket. Extruded PTFE, FEP, ETFE, PVC or PFA with 2 mils minimum wall thickness at any point, or PETP with a PVC or polyester adhesive (Milene) with 2 mils minimum wall thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Class 2 circuits in electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024