|
Rating | 80 deg C, 30 Vac, Cable flame. |
|
Insulation | Labeled or complying with manufacturer's Procedure. |
|
Assembly | Flat ribbon cable folded or spiraled layers. Section may be slit into singles of two to 100 in length. Fillers optional. |
|
Shield | Optional. |
|
Jacket | PVC |
| major dia in inches |
| 0.700 or less | 30 mils min average | 24 mils minimum at any point |
| 0.701-1.000 in | 45 avg | 36 min |
| 1.001-1.500 in | 60 avg | 48 min |
| 1.501-2.500 in | 80 avg | 64 min |
| 2.501-4.000 in | 110 avg | 88 min |
| 4.001 in or large | 140 avg | 112 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of electronic equipment |
|