Rating | 105 deg C, 150 Vac or 300 Vac, Horizontal flame. |
|
Conductor | 40 AWG - 24 AWG solid or stranded. |
|
Insulation | Extruded TPE, 6 mils minimum average thickness. |
|
Assembly | Two to 150 conductors laid parallel. Optional fiiler. Top or bottom layers may form ridges over conductors. |
|
Shield | Optional. |
|
Covering | Optional. Extruded PVC, extruded TPE, or extruded Polyolefin, 4 mils minimum thickness at any point, 80 mils maximum thickness. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring. |
|