APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20677 Issued:1991-02-28
Revised:2012-05-29
Style 20677 Multiple-Conductor Cable using Non-Integral Extruded Jacket.

Rating105 deg C, 300 Vac, FT2 Flame.
Conductor18 AWG, Consisting of sixteen 30 AWG stranded round.
InsulationExtruded PVC, 15 mils minimum average, 13 mils minimum at any point.
AssemblyThirteen conductors, same as type SVT, cabled together with fillers as required.
CoveringNon-Extruded Binder Tape - SBR/Cotton.
JacketExtruded TPE, 30 mils minimum average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or External Interconnection.