| Rating | 80 deg C, 300 Vac, FT-2 Flame. |
|
| Conductor | 20 AWG stranded, consists of 10 strands of No. 30 AWG. |
|
| Insulation | Extruded SRPVC, 9 mils minimim average thickness, 7 mils minimum thickness at any point. |
|
| Assembly | 9 pairs of insulated conductors. Each pair is provided with an overall polyester separator. The 9 pairs are cabled together with a separator and an overall copper braid. |
|
| Covering | Polyester wrap. |
|
| Shield | Copper braid. |
|
| Jacket | Extruded TPE, 30 mils minimum average thickness, 24 mils minimum thickness at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring or external interconnection of robotic equipment where the acceptability of the combination is to be determined by Underwriters Laboratories Inc. |
|