| Rating | 80 deg C, 300 Vac, FT2 flame. |
|
| Conductor | 22 AWG (ten strands of 30 AWG), 20 AWG (seven strands of 30 AWG), tinned or bare copper. |
|
| Insulation | Extruded SRPVC, 9 mils minimum average thickness, 7 mils minimum thickness at any point. |
|
| Assembly | Fourteen (seven pairs) 22 AWG and six (three pairs) 20 AWG cabled together with an overall polyester binder, a copper braid, and overall polyester separator. |
|
| Jacket | Extruded TPE, 30 mils minimum average thickness, 24 mils minimum thickness at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring or external interconnection of robotic equipment where the acceptability of the combination is to be determined by Underwriters Laboratories Inc. |
|