APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20687 Issued:1991-03-18
Revised:2012-07-29
Style 20687 Multiple Conductor Cable with Extruded Insulation with an Extruded Non-integral Jacket.

Rating60 deg C, no voltage assigned, Horizontal flame.
Conductor36 AWG - 18 AWG stranded round or tinsel.
InsulationExtruded PBE or extruded PBT or extruded PE or extruded PP or extruded TPE or extruded TPEE or extruded TPES - THERMOPLASTIC POLYESTER, 6 mils min average, 5 mils min at any point.
AssemblyTwo to ten insulated conductors cabled straight or wound in retractile form. Core may be either flat or round.
ShieldOptional. one or more may be shielded.
CoveringOptional. Extruded Polyester, 2 mils min at any point.
JacketExtruded PVC, 15 mils min average, 12 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseAs "Handset Wire or Telephone Cord for Subscriber Sets".