|
Rating | 90 deg C, 150 Vac, Cable flame. |
|
Conductor | 36 AWG minimum. solid or stranded. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. The designations of all styles of individual conductors used in making up the cable assembly shall be available. |
|
Assembly | Two or more individually insulated conductors Assemblyor groups of insulated conductors cabled together to form a round cable. A flat or oval cable may also be constructed with not more than three rows of single conductors or groups of conductors. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic tape wrap. The barrier layer may be applied over the twisted assembly of individual conductors, groups of conductors or individual conductors or over the shield, if provided. |
|
Shield | Optional. |
|
Jacket | PUR |
| major dia in inches |
| 0.700 or less | 30 mils min average | 24 mils minimum at any point |
| 0.701-1.000 in | 45 avg | 36 min |
| 1.001-1.500 in | 60 avg | 48 min |
| 1.501-2.500 in | 80 avg | 64 min |
| 2.501-4.000 in | 110 avg | 88 min |
| 4.001 in and larger | 140 avg | 112 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External wiring. |
|