| Rating | 60 deg C, 150 Vac, Cable flame. |
|
| Conductor | 40 AWG min. solid or stranded. |
|
| Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
| Assembly | Consists of two or more singles, twisted pairs or groups of twisted singles twisted together. The singles or groups of singles may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
| Shield | Optional. |
|
| Covering | Optional. A 6 mil or heavier PVC covering may be extruded over the conductor assembly. |
|
| Jacket | Extruded PVC, major dia. of 0.700 inches or less, 30 mils minimum average thickness, 24 mils minimum thickness at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | External interconnection of electronic equipment or internal wiring of electronic equipment or appliances. |
|