APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20694 Issued:1991-06-14
Revised:2012-04-26
Style 20694 Multi-conductor Cable with Extruded Non-Integral Jacket.

Rating80 deg C, Voltage not specified, Cable flame.
Conductor40 AWG minimum. solid or stranded round.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of single, twisted conductors twisted together. The conductors or groups of conductors are laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional. Extruded TPU, 6 mils minimum thickness at any point. May be over the conductor assembly.
JacketExtruded TPU
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
3.200 inches or less30 mils24 mils
3.201-4.000 inches45 mils36 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.