Rating | 80 deg C, Voltage not specified, Cable flame. |
|
Conductor | 40 AWG minimum. solid or stranded round. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of single, twisted conductors twisted together. The conductors or groups of conductors are laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional. |
|
Covering | Optional. Extruded TPU, 6 mils minimum thickness at any point. May be over the conductor assembly. |
|
Jacket | Extruded TPU |
| Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 3.200 inches or less | 30 mils | 24 mils |
| 3.201-4.000 inches | 45 mils | 36 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring. |
|