APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20695 Issued:1991-06-13
Revised:2012-03-22
Style 20695 Multiple-conductor cable using non-integral jacket

Rating60 deg C, Voltage rating not specified, Cable flame.
Insulated ConductorNo. 40 AWG min. Labeled or complying with manufacturer's AWM Procedure having a min rating of 60 deg C.
AssemblyConsists of two or more conductors, twisted pairs or groups of single, twisted conductors twisted together. The conductors or groups of conductors are laid parallel forming a flat cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
CoveringOptional. A 6 mil or heavier PVC covering may be extruded over the conductor assembly.
ShieldOptional.
JacketPVC, dia. or 4.0 inches or less, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.